CICS-CONSOLE-ERROR

 

ERZ010144I/0375 03/28/18 11:10:20.173027000 MQ 5304/0001 : Application server 101 started

ERZ024118I/0312 03/28/18 11:10:20.173245000 MQ 5304/0001 : Application Server 101 is playing back work that took place after the last checkpoint

1 5304 18/03/28-11:10:21.290365 6c1c041c T ppc_tcpSockInit: gethostbyname error: cics not found

1 5304 18/03/28-11:10:21.290748 0000000c T /cics/ServLvl/encsrc/src/ppc/tcp/ppc_tcpSock.c 872

ERZ010040I/0055 03/28/18 11:10:21.290834000 MQ 5304/0001 : CICS control process ‘cicsas’ terminated

ERZ010089E/0367 03/28/18 11:10:21.292223000 MQ 4927/0008 : Application Server 101 PID 5304 ended unexpectedly

ERZ010144I/0375 03/28/18 11:10:22.303388000 MQ 5312/0001 : Application server 101 started

 

 

 

 

區域啟動失敗的原因

如果區域啟動失敗,請檢查以下項:

  • 檢查 /etc/hosts 的文件許可權,是否設置為 rw-r-。您需要將 /etc/hosts 的文件許可權更改為 rw-r–r–。不正確的許可權會導致以下錯誤:
  • ERZ010144I/0375 Application server 157 started
  • 1 14922 6c1c041c T ppc_tcpSockInit: gethostbyname error: localhost not found

    14922 0000000c T 816 /afs/transarc.com/product/encina/field/pdg/4.3/source/src/ppc/tcp/ppc_tcpSock.c

  • 確保 cics 組在 /var/cics_servers/  /var/cics_regions/ 中具有足夠的寫權限。
  • 區域啟動失敗並顯示 ERZ060008E,隨後區域報告 U 異常終止 (U4803)。這是因為一個不同的庫被裝入到為區域的共享池內存指定的地址。您可以將區域池的基地址(RD 中的 RegionPoolBase)更改為不同的分段然後重試。

     